496334 Issue 1 9 of 14
To change: Key-in: Notes Default
Duress mode 24 0 Audible
1 Silent Y
Internal Sounder 25 0 Follows external bell Y
1 Continuous
Sounder Delay on Entry 26 0 Normal
1 Delay always Y
PA Response 30 0 Audible Y
1 Silent
Night Line Fault Response 31 0 Full alarm
1 No alarm Y
Day Line Fault Response 32 0 Audible Y
1 Silent
System Reset 33 0 User reset Y
1 Engineer reset
PA Reset 34 0 User reset Y
1 Engineer reset
First circuit lockout 35 0 Lock out Y
1 Re-arm
Entry Abort 36 0 Disabled Y
1 Enabled (90 seconds abort time)
Day tamper comms † 37 0 Disable (local audibles only) Y
and Engineer on Site 1 Enabled, communicator channel 5
Keypad Input 38 0 Exit terminate Y
1 Keyswitch
2 Lockset
Exit Mode 39 0 Timed or terminate set Y
1 Final door set
2 Lock set
Auto Re-Arm 40 0 Never
1 Once Y
2 Twice
3 Three times
4 Always
Bell Delay 41 0 No delay Y
1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes
7 Infinite delay