22 of 44 496339 Issue 1
IDIS Programming Errors
You may see one of the following messages on the second line of the display
while programming IDIS modules/sensors. If so follow the procedure indi-
cated.
OUT OF RANGE The module is blank or incorrectly programmed.
Carry on and try to program the module. If you do
not succeed then use a new device and return the
original to the manufacturer.
NOT IDIS ZONE You have tried to program a zone number less than
9. Zones 1 to 8 are FSL zones.
NO DEVICE FOUND There is nothing connected to the programming
pins on the IDIS Expander card.
DEVICE FAULTY The system failed to program the device. Try again
to program the module. If you do not succeed then
use a new device and return the original to the
manufacturer.
FREQUENCY ERROR The device or module is not programmed correctly.
Try again to program the module. If you do not
succeed then use a new device and return the
original to the manufacturer.
NON SCANTRONIC The module is not a Scantronic IDIS device. The
module cannot be used.
Programming Zones
Figure 11. The Zone Display for Menu 32
Zone Types. You assign each detector a zone type so that the control panel
can give the appropriate response. Types include, for example, normal
alarms, 24hour alarms, fire alarms and several others.
Zone Attributes. You can further modify the way the control panel responds
to each zone by assigning a zone attribute. For example, the “chime” attribute
allows you to program the panel to sound a chime tone every time a particu-
lar detector is triggered.
IDIS Programming Errors 8136