496372 Issue 1 17 of 34
Testing
You can switch the 4604-55 on so that it transmits a continuous test signal.
This facility helps in range-testing and fault-finding. To activate the test signal
turn the switch marked TEST (on the 2-way DIL switch) to ON.
Figure 12. ON/OFF and Test Switches
To ensure good reception use the Scantronic 4690 field strength meter to
obtain accurate field strength readings and audible and visual indication of
the transmitter’s performance and any interference present.
Turn the TEST switch OFF when you have completed testing, or the trans-
mitter will block ALL radio signals to your receiver!
Final Commissioning
When you are satisfied with the position and channel transmission character-
istics replace the lid. Insert the lid into the bottom of the base. Slowly push
the lid in until it locks into the retaining clip. CAUTION Take care not to bend
or disturb the wire aerial.
Refit the screw and tighten firmly into the base. The red LED lights and the
transmitter sends a closed tamper signal.
Note: DIL switch changes will not take effect until the transmitter is operated twice.
4605
Introduction
The 4605-55 dual function transmitter can be used as a personal attack
transmitter/remote setting device for a 4600 alarm panel, or as a 2-channel
transmitter with the 4612 or 4618/9 receivers and 4660/75 consoles.
To use the 4605 as personal attack button press the two orange side buttons
together. The transmitter does not signal if you press only one button. Note:
the black button fitted below the left-hand orange button. This is a safety lock
to prevent false activations. Slide the black button upwards to lock the orange
button.
4605
Kommentare zu diesen Handbüchern