496372 Issue 1 21 of 34
Tilt Switch - The buzzer starts a warning tone approximately 12 seconds
after the unit tilts more than 45 degrees from vertical. The warning tone lasts
for 12 seconds while the unit is tilted. At the end of the warning tone the unit
sends an alarm signal to the receiver if it is still tilted. Restore the unit upright
to silence the warning tone.
Manual Over-Ride - Press the grey button on top of the unit to temporarily
disable the tilt switch. After you press the button the unit ignores the tilt switch
for 7 minutes. At the end of that time the unit will sound the buzzer as it
comes back into use. Press the grey button again for another delay. This
facility lets you work without causing false alarms.
Technical Specification
Dimensions h x w x d 102 x 44 x 20mm.
Input supply 3.7V Lithium battery.
Temperature -10°C to +55°C. Humidity up to 80% (non
condensing).
Frequency 173.225 MHz.
Power output 1mW.
Fully DTI approved to MPT1344 for alarm use only. No licence required.
BS6799:1986 Classes 1-3.
Coding The Transmitter
Remove the self-tapping screws and carefully ease the top of the case
upwards. Set the site code on the large 10-way DIL switch. Note that UP is
ON and DOWN is OFF. Do not set all switches to ON or the transmitter will
not work correctly.
NOTE: The 4606-55 is not compatible with the 4611/4613 single channel receivers.
4600
Use the same switch settings given for 4604. Tilt is Tamper, the two side
buttons are Alarm.
4612
Set switches as described for the 4605.
4618/9
Set switches as described for the 4605.
4660/75
Refer to the appropriate installation manual.
4606