496372 Issue 1 33 of 34
4624
c) To allow a second 4624 to output to channels 5 - 8 on the receiver, set
switch number 8 on the transmitter to ‘Off’.
Note: Switch number 8 on the 4618/9 Receiver Identification switch can be in any
position.
For more information refer to 4618 Installation Guide.
Identification Code Selection 4612
Set switches 1-8 on the 4624, to the site code of the 4612. Set switches 9-10
on the 4612 to off and set the mode switch for 2-Channel. Leave channels C
and D on the 4624 open, e.g., unlinked.
Operation
Channel A on the 4624, operates channel A on the 4612.
Channel B on the 4624, operates channel B on the 4612.
Note : For more information, refer to ‘4612 Installation Guide’.
Identification Code Selection 4660/75
Refer to the appropriate Installation Manual.
Note : The 4624 is not compatible with the 4600 or 4611/4613 receivers.
Low Battery (Power) Reporting
The transmitter constantly monitors the input power voltage. If it drops to 9.5
volts +/-1 volt for more than 2 minutes, the transmitter will automatically
transmit the state of all inputs and ‘low battery’. This will be transmitted every
2 minutes thereafter until the voltage has been restored to a nominal 12 volts.