Pin Alarm Polarity
The pin alarm channels respond to the voltage level at the terminal block inputs
(stand-alone mode) or the pins of SK1 and SK2 (plug-in mode). The appropriate
terminal block inputs and plug-in connector socket pins are tracked together in
parallel on the circuit board. Each channel can be programmed to be "Positive
Applied" or "Positive Removed". This polarity is set in the NVM.
PROGRAMMING THE NVM
For 11zstu, the NVM programming does not affect the functions of alarm
channels 9, 10, 11 and AC Fail. The extra alarm inputs are configured by DIP
switches on the expansion board. All unused alarm inputs must be disabled. For
all enabled alarm inputs, the correct polarity must be selected. Alarm inputs 9,
10 11 and AC Fail cannot be selected as opening/closing channels.
Switches at SW1 are used to enable or disable and to select the polarity of the
extra alarm inputs. The function of each switch is indicated in the table below.