Input Switch Off On
1 Negative Applied Positive Applied
9
2 Disabled Enabled
3 Negative Applied Positive Applied
10
4 Disabled Enabled
5 Negative Applied Positive Applied
11
6 Disabled Enabled
7 Negative Applied Positive Applied
AC Fail
8 Disabled Enabled
Remote Programming
Once installed, the NVM can be re-programmed remotely by the ARC. Only
the relay states can be adjusted unless a technician is on-site to set the STU
into Secure Access Mode using LK3. Remote NVM programming is not
available on the 11zstu or on older units that do not have LK3 fitted.
Contact BT redcare for more information.
Manual Programming
NVMs can be programmed using a Scantronic 7200 or 7300 NVM
programmer.
Apply power to the programmer (12 V DC or 12 V AC.) and set the on/off
switch to position "0".
Insert the NVM in the socket marked ‘COPY NVM’. Ensure that the dot on
the NVM lines up with the white dot on the programmer.
Set the on/off switch to position ‘1’ and wait for the programmer to display
its version information and follow the instructions below: