2. Everyday Operation
The 808 provides several different ways for setting the system. All methods
(except using a Keyswitch) require entering your access code at the key-
pad. The Keyswitch method uses a key in a special switch fitted outside your
premises. "Setting the System" below describes each method. Ask your
Installer to provide the method that suits your site best.
During installation the Installer programs the system to create an exit route
for your premises. When setting the system you must follow this route to
leave the premises. Similarly you must follow a specified entry route when
going into the premises in order to unset the system. If you stray from these
routes you may cause a false alarm.
Note: The system may be programmed so that your access code can set some
Levels but not others. See "5. Supervisor".
Setting the System
Timed Setting
With Timed Setting the system sets after a programmed exit time. Ask your
Installer to make sure the exit time is long enough for you to leave the
premises and close the final door. The exit time starts when you finish enter-
ing the set command at the keypad. During the exit time the keypads give a
continuous exit tone to warn you that the timer is running. If you hear an
interrupted tone from the keypad when you try to set the system then one of
the doors on the exit route is open. Make sure that they are all closed.
1. Close all doors and windows.
2. Key in your access code at the keypad.
3. Press the appropriate Level button.
The keypad starts the continuous exit tone, the
Level LED flashes, and the display shows: READY LEAVE
4. Leave via the designated exit route. Close the final door.
At the end of the exit time the system sets, and stops the exit tone. The
Level LED glows to show which Level is set.
You can also set the system by entering your access code and pressing
Enter. The system will set to the highest Level that the Installer has pro-
grammed.
If you do not close the final door before the end of the exit time then the
system gives an internal alarm and does not set. Go back to the keypad and
unset the system, see "3. After an Alarm".